mirror of
https://github.com/rad4day/Waybar.git
synced 2023-12-21 10:22:59 +01:00
Merge pull request #1105 from Amanieu/fix_power_calc
Fix power calculation when battery units are in μA instead of μW
This commit is contained in:
commit
bad72de960
@ -162,25 +162,36 @@ const std::tuple<uint8_t, float, std::string, float> waybar::modules::Battery::g
|
|||||||
uint32_t energy_full_design;
|
uint32_t energy_full_design;
|
||||||
std::string _status;
|
std::string _status;
|
||||||
std::ifstream(bat / "status") >> _status;
|
std::ifstream(bat / "status") >> _status;
|
||||||
auto rate_path = fs::exists(bat / "current_now") ? "current_now" : "power_now";
|
|
||||||
std::ifstream(bat / rate_path) >> power_now;
|
|
||||||
|
|
||||||
std::string now_path;
|
// Some battery will report current and charge in μA/μAh.
|
||||||
if (fs::exists(bat / "charge_now")) {
|
// Scale these by the voltage to get μW/μWh.
|
||||||
now_path = "charge_now";
|
if (fs::exists(bat / "current_now")) {
|
||||||
} else if (fs::exists(bat / "energy_now")) {
|
uint32_t voltage_now;
|
||||||
now_path = "energy_now";
|
uint32_t current_now;
|
||||||
} else {
|
uint32_t charge_now;
|
||||||
now_path = "capacity";
|
uint32_t charge_full;
|
||||||
|
uint32_t charge_full_design;
|
||||||
|
std::ifstream(bat / "voltage_now") >> voltage_now;
|
||||||
|
std::ifstream(bat / "current_now") >> current_now;
|
||||||
|
std::ifstream(bat / "charge_full") >> charge_full;
|
||||||
|
std::ifstream(bat / "charge_full_design") >> charge_full_design;
|
||||||
|
if (fs::exists(bat / "charge_now"))
|
||||||
|
std::ifstream(bat / "charge_now") >> charge_now;
|
||||||
|
else {
|
||||||
|
// charge_now is missing on some systems, estimate using capacity.
|
||||||
|
uint32_t capacity;
|
||||||
|
std::ifstream(bat / "capacity") >> capacity;
|
||||||
|
charge_now = (capacity * charge_full) / 100;
|
||||||
}
|
}
|
||||||
std::ifstream(bat / now_path) >> energy_now;
|
power_now = ((uint64_t)current_now * (uint64_t)voltage_now) / 1000000;
|
||||||
auto full_path = fs::exists(bat / "charge_full") ? "charge_full" : "energy_full";
|
energy_now = ((uint64_t)charge_now * (uint64_t)voltage_now) / 1000000;
|
||||||
std::ifstream(bat / full_path) >> energy_full;
|
energy_full = ((uint64_t)charge_full * (uint64_t)voltage_now) / 1000000;
|
||||||
auto full_design_path = fs::exists(bat / "charge_full_design") ? "charge_full_design" : "energy_full_design";
|
energy_full_design = ((uint64_t)charge_full_design * (uint64_t)voltage_now) / 1000000;
|
||||||
std::ifstream(bat / full_design_path) >> energy_full_design;
|
} else {
|
||||||
|
std::ifstream(bat / "power_now") >> power_now;
|
||||||
if (now_path == "capacity") {
|
std::ifstream(bat / "energy_now") >> energy_now;
|
||||||
energy_now = energy_now * energy_full / 100;
|
std::ifstream(bat / "energy_full") >> energy_full;
|
||||||
|
std::ifstream(bat / "energy_full_design") >> energy_full_design;
|
||||||
}
|
}
|
||||||
|
|
||||||
// Show the "smallest" status among all batteries
|
// Show the "smallest" status among all batteries
|
||||||
|
Loading…
Reference in New Issue
Block a user